ENGINEERED FOR US MARKET
CONFIGURABLE KVA / VOLTAG
FAST DELIVERY & SUPPORT
We support the full lifecycle of your transformer — from installation and commissioning to preventive maintenance, diagnostics and modernization. Our engineering team ensures safe integration, reliable long-term operation and improved system performance across industrial, utility and renewable applications.

Safe, compliant and precise transformer integration
Safe, compliant and precise transformer integration
Our installation and commissioning service ensures your transformer is deployed correctly, safely and in full alignment with system requirements.
What’s included:
• Site evaluation and preparation
• Positioning, assembly and connection of the transformer
• Protection and control settings configuration
• Verification of tap changer operation
• Oil filling, filtration and testing (if required)
• Functional checks of cooling, monitoring and protection systems
• System energization under engineer supervision
• Commissioning report and documentation package
Outcome:
Your transformer enters service safely, efficiently and with verified performance parameters.

Proactive care to maximize reliability and extend asset life
Proactive care to maximize reliability and extend asset life
Our maintenance services help prevent failures, reduce unplanned downtime and maintain stable transformer performance under real-world conditions.
What’s included:
• Scheduled inspections and electrical testing
• Thermal imaging and hotspot diagnostics
• Oil sampling and DGA (Dissolved Gas Analysis)
• Monitoring of bushings, windings and insulation condition
• Load profile evaluation and performance optimization
• Verification of cooling system performance (ONAN/ONAF/OFAF)
• Review of OLTC/DETC tap changer health
• Digitized condition reports for asset management
Outcome:
Improved reliability, early issue detection and lower long-term maintenance costs.

Restore performance or upgrade to modern standards
Restore performance or upgrade to modern standards
When equipment begins to age or fails, we provide full repair and modernization services to restore or improve transformer functionality.
What’s included:
• Component replacement (bushings, gaskets, radiators, cooling fans, sensors)
• Forced-air or forced-oil cooling system upgrades
• Rewinding of HV/LV coils
• Core tightening and insulation repairs
• OLTC/DETC overhaul or replacement
• Modernization for improved short-circuit withstand
• Installation of remote monitoring systems
• Firmware upgrades and documentation validation
Outcome:
Extended transformer service life, reduced risk of failure and improved operational efficiency.

High-quality transformer components and replacement parts
High-quality transformer components and replacement parts
We supply a full range of transformer accessories and replacement components to support installation, maintenance and long-term operation.
Core Accessories:
• WTI / OTI Thermometers
• Buchholz Relay
• Radiators
• Cooling Fans
• Oil Pumps
• HV & LV Bushings
• Oil Level Gauges
Tap Changer Parts:
• Federal Pioneer components: TC-23, TC-23-2, TC-15, TC-546, TC-34
• Molded parts: Diverter switches, selector shafts, tap heads, CT blocks, diverter push rods, DTC switch decks
Additional Components:
• Gaskets & sealing kits
• Temperature sensors
• Pressure relief devices
• Oil sampling valves
• Control cabinets & wiring accessories

Our engineering team will help you select the right kVA, voltage and cooling options and guide you through specification, documentation and project planning.
Describe the item or answer the question so that site visitors who are interested get more information. You can emphasize this text with bullets, italics or bold, and add links.
Describe the item or answer the question so that site visitors who are interested get more information. You can emphasize this text with bullets, italics or bold, and add links.
Describe the item or answer the question so that site visitors who are interested get more information. You can emphasize this text with bullets, italics or bold, and add links.
Describe the item or answer the question so that site visitors who are interested get more information. You can emphasize this text with bullets, italics or bold, and add links.
Describe the item or answer the question so that site visitors who are interested get more information. You can emphasize this text with bullets, italics or bold, and add links.
Describe the item or answer the question so that site visitors who are interested get more information. You can emphasize this text with bullets, italics or bold, and add links.
Describe the item or answer the question so that site visitors who are interested get more information. You can emphasize this text with bullets, italics or bold, and add links.
Describe the item or answer the question so that site visitors who are interested get more information. You can emphasize this text with bullets, italics or bold, and add links.
Describe the item or answer the question so that site visitors who are interested get more information. You can emphasize this text with bullets, italics or bold, and add links.
Describe the item or answer the question so that site visitors who are interested get more information. You can emphasize this text with bullets, italics or bold, and add links.
Describe the item or answer the question so that site visitors who are interested get more information. You can emphasize this text with bullets, italics or bold, and add links.
Our team will help you choose the right kVA, voltage and cooling configuration for your industrial, utility or renewable application.



Built for Reliability. Engineered for Performance.
Get in touch
© 2025 LIMIK. All Rights Reserved.